Products
What is parallel mode in power supplies?
Parallel mode distributes the current equally between power supplies that are connected in parallel. In parallel mode, the output voltage is regulated so that at no load it is around 5% higher than at nominal load.
What is the power factor of a power supply?
The power factor or cos phi of a power supply is the ratio between the real power and the apparent power.
What does redundancy mean in the context of power supplies?
The reliability and availability of the DC voltage can be increased with the help of a redundant system. To create a redundant system, an additional power supply must be installed in reserve. This power supply then provides the necessary load current if another power supply in the system fails.
Which protection classes are used for electrical equipment?
The IEC/EN 61140 standard classifies electrical equipment according to its safety with regard to shock currents and electric shocks.
What is a shutdown input?
A shutdown input is a signal input that allows a power supply to be shut down by means of an externally supplied voltage or a simple switch. A shutdown input is galvanically isolated from the input voltage and can be supplied by separated extra-low voltage (SELV) circuits.
What does the term “surge” mean?
A surge is a transient voltage (e.g. on the mains power line) caused by nearby lightning strikes or inductive voltage spikes after a circuit breaker has been triggered by a short circuit.
How does the overload behaviour of power supplies work?
All PULS power supplies have outputs that are overload-proof, short-circuit-proof and no-load-proof. No external fuse is required on the output to protect the power supply.
What is overshoot in a power supply?
Overshoot is the amount by which the output voltage exceeds its static value when there is a rapid change in the load or in the input voltage or when the input voltage is connected.
How does overtemperature protection function in power supplies?
Overtemperature protection causes an emergency shutdown. It prevents thermal damage being caused to a switch-mode power supply or a failure of isolation as a result of excessively high temperatures.
How is the ambient temperature of a power supply defined?
The ambient temperature is the air input temperature two centimetres below the power supply.
What does UPS mean?
A UPS or uninterruptible power supply is a power supply with VRLA batteries or capacitor storage that can supply the connected devices with power for a specific period in the event of a power failure.
What is a VDE 0160 pulse?
A VDE 0160 pulse is a high-energy voltage pulse that can occur in the mains voltage of industrial networks (e.g. when shutting down large loads or after short circuit currents have subsided).
What are VRLA batteries?
Valve-regulated lead acid (VRLA) batteries are sealed batteries fitted with a safety valve that allows the gas produced by overcharging or a cell fault to escape.
What does efficiency mean in the context of power supplies?
The efficiency value is the ratio of the output power to the input power of a power supply. The difference between the input and output power is converted as power losses into heat.
What is an X capacitor?
These capacitors are approved for suppressing radio interference and are installed between the phase and the neutral wire or between the phases. They provide protection against differential mode interference.
What is a Y capacitor?
These capacitors are approved for suppressing radio interference and are installed between the phase(s) and the housing or protective earth wire or between the neutral wire and the housing or protective earth wire. They provide protection against common mode interference.